CGBFK - QD CONTACT CLEANER (BULK), 2132

  • MSDS: CGBFK
  • Manufacturer: CRC INDUSTRIES IND
  • Product Name: QD CONTACT CLEANER (BULK), 2132
  • National Stock Number: 7930-00N081394
Product Identification

Product ID:QD CONTACT CLEANER (BULK), 2132
MSDS Date:12/18/1991
FSC:7930
NIIN:00N081394
MSDS Number: CGBFK

Responsible Party
CRC INDUSTRIES IND
885 LOUIS DR
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Preparer: ROBERT KUKLENTZ

Cage: CRCIN

Contractor
CRC INDUSTRIES, INC.
WARMINSTER, PA 18974-2820 US

Telephone: 215-674-4300/800-424-9300

Cage: 10136

Ingredients

ETHYL ALCOHOL (ETHANOL)

CAS: 64-17-5

RTECS: KQ6300000

Fraction By Weight: 10%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


HEXANE (CERCLA)

CAS: 110-54-3

RTECS: MN9275000

Fraction By Weight: 9%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


PENTANE, 2-METHYL-; (ISOHEXANES)

CAS: 107-83-5

RTECS: SA2995000

Fraction By Weight: 81%

OSHA PEL 500 PPM (MFR)

ACGIH TLV: 500 PPM (MFR)

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: BURNING AND IRRITATION.
SKIN: MILD IRRITATION. INHALATION: IRRITATION OF RESPIRATORY TRACT,
DIZZINESS, HEADACHES, CENTRAL NERVOUS SYSTEM. CHRONIC: REPEATED
OVEREXPOSURES MAY CAUSE HARM TO THE NERVOUS SYSTEM.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:PRE-EXISTING LUNG DISORDERS.

First Aid

First Aid:IF SYMPTOMS PERSIST, CALL A PHYSICIAN. INHAL: REMOVE TO FRESH
AIR. APPLY ARTIFICIAL RESPIRATION IF NECESSARY. EYES: FLUSH W/LARGE
AMOUNTS OF WATER FOR @ LST 15 MINUTES. SKIN: WASH AREA W/SOAP AND
WATE R. INGEST: DO NOT INDUCE VOMITING. CALLPHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:<20F,<-7C
Lower Limits:1%
Upper Limits:19%
Extinguishing Media:DRY CHEMICAL, CO*2, OR FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPORS GENERATED ARE EXTREMELY FLAMMABLE.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF IGNITION. VENTILATE AREA.
ABSORB SPILL WITH AN INERT ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY AREA.
Other Precautions:USE PRODUCT IN AREA WITH GOOD VENTILATION. VAPORS ARE
HEAVIER THAN AIR AND WILL COLLECT IN LOW AREAS.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED SELF-CONTAINED BREATHING
APPARATUS ABOVE THE TLV.
Ventilation:MAINTAIN VAPOR CONCENTATION BELOW TLV. USE MECHANICAL MEANS
IF NECESSARY.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (SUPDAT)
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . BOOTS
AND APRON IF POSSIBILITY OF BODY CONTACT EXISTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EYE PROT:& FULL LENGTH FACESHIELD .

Chemical Properties

Boiling Pt:B.P. Text:141F,61C
Melt/Freeze Pt:M.P/F.P Text:<0F,<-18C
Vapor Density:>1
Spec Gravity:0.692
Evaporation Rate & Reference:>1 (BUTYL ACETATE =1)
Solubility in Water:PARTIAL SOL IN WATER
Appearance and Odor:CLEAR LIQUID WITH ALCOHOL ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, STRONG ACIDS OR BASES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO*2, CO (THERMAL).

Disposal

Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED
OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.